Attn: Master And Chief Engineer
Please note that during recent PSC inspection onboard one of
our vessel at Nakhoka, Russia, flowing observation noted.
Deficiencies as under:
1. Supplement
to IOPP, Form B - page 3,2A.Oil Fuel tank protection (regulation 12A) not
checked as required (2.A.1 or 2.a.2).
2. Supplement
to IOPP, form B-page 4 found in photocopy.
3. No
procedures implements with some type of waste (fluorescent lamps, Battery,
Medicine etc.), But store in CCR, In Duty Mess Room.
4. Fire
protection self - closing door (Accommodation interior stairway B,C door not
closing fully.
5. Some of
navigation charts for engaged voyage found in scan copy
6. Scan copy
charts are not up - date by 1237(T)/2006.
7. Magnetic
compass deviation not properly adjusted.
8. Magnetic
compass found with air big bubble.
9. Magnetic
compass illumination in a bad condition.
10. FWD anchor
light (spare) out of order.
11. steering
gear l.o gravity tank air vent cover securing bolt missing.
12. D/Generator
exhaust air vents protective gratings (funnel deck)Found dirty (oil on gratings
and on the deck)
13. In
emergency room found unapproved battery charger (Electrical cables, socket was
hanging on pipes)
14. Emergency
generator room fixed battery charger electrical cable not secured.
15. Foam applicator
unit plastic can (one) damage (Foam solution quantity less than 20 Lt)
16. Food waste
drum cover not ensured tightened covered as required by GMP, Item 10.5 (c).
17. Steering
gear hatch cover not fixed in open position due to hole less than diameter of
securing bolts.
18. tanks
washing system water pipe flange bonding cable damaged.
19. Fixed deck
foam fire extinguisher system balanced pressure proportional with much stains
of leakage.
20. Balanced
Pressure proportioner not adjusted foam
concentration ratio.
21. Much of
oil strains found on incinerator sludge tank body, on top, on ceiling above the
sludge tanks, due to accident, but not records found in E/R log book, or Deck
log book.
22. incinerator
sludge tank detectors (Overfill and sludge pump auto - stop) out of order
(Level of sludge higher than position of detector).
23. Main
engine exhaust pipe inlet valve open/close indicator electrical cable
disconnected (to composite boiler).
24. Fuel oil
pipe sighting glass from purifier to setting tank dirty, oil leakage through
flange connection.
25. E/R
portable foam fire extinguishers (two)seal missing)
26. Electrical
cable (above M/E scav box) excessively dirty by stains of salt water.
27. E/R Low
platform plating not secured (part of emergency exit way with ledge).
28. throughout
of E/R found pressure gauge with stains of leakage (M/E fresh water cooler,
no.1 & no.2 I.G scrubber cooling S.W pump, no.1 main cooling S.W pump etc.)
29. E/R lower
platform alarm panel partly damaged.
30. Maintenance
and inspection of fire protection system and equipment inadequate.
31. Above deficiencies
mainly caused by lack of maintenance , maintenance routine below standard.
32. ISM system
does not ensure adequate maintenance of ship and equipment.